14.3
Main Menu
The Main Menu contains three sections, FILE, DEVICE, INTERFACE and HELP.
14.3.1
File
Click on Open (or press
F2
) to load a configuration from disc.
Click on Save (or press
F3
) to save a configuration to disc.
Save Hex is an OBR feature only.
Admin is an OBR feature only.
Click on Exit (or press
F7
) to c lose the MSP tool.
14.3.2
Device
Click on Read (or press
F8
) to read a configuration from the MSP.
Reading the configuration from the panel, the following information is displayed:
- Controller serial number.
- Panel version (keypad configuration).
- Hardware version, 1 (version 2009 to 2014) or 2 (the revised
controller from 2015).
- Panel user name.
Click on Write (or press
F9
) to send a configuration file to the MSP.
The panel will reset and use the new configuration.
Click on Reset (or press
F10
) to reset the controller manually.
14.3.2.1
Firmware Update
It is possible to update the current version of firmware with new
releases.
Click on Firmware (or press
F6
) to locate the firmware BIN file and
click OK to load the firmware into the programmer.
The Firmware Update Instructions window opens, click OK to update
the firmware in the controller.
Please note that firmware can
only
be updated if the tool and
controller are set to communicate on addresses
0x60
(Panel
Transmit, Send ID1) and
0x790
(Panel Receive, Receive ID1).
IMPORTANT:
You must send the MSP configuration file to the panel
after having updated firmware.
14.3.3
Interface
In this section you can select:
- Type of interface used, Peak or EFI Technology
- Baud rate used, select between 10 kbps up to 1 Mbps.
14.3.4
Help
- Click on Help Topics to open the help file.
- Click on About to check MSP software version.