All switch inputs can be configured as latching or momentary in the software.
This means that using momentary acting switches it is possible to control the switching in two
different ways:
Set as momentary, the SWC registers the signal ON as long as the switch is pressed.
Set as latching, press the switch once to turn ON, press the switch again to turn OFF.
Using this setup the diodes shown in the diagram are not required.
Some installations are done by using conventional toggle switches. These switches will provide a
constant trigger signal. To avoid any unintended switching the diodes shown in the diagram must
be used.
Using these toggle switches all iSWC inputs must be set to be momentary inputs.
The SWC shares the software with our MSP.
Connections:
Pin
Name
Description
J1
LED -2
SWITCH 2 LED
J2
LED - 3
SWITCH 3 LED
J3
LED - 5
SWITCH 5 LED
J4
LED - 7
SWITCH 7 LED
J5
LED - 9
SWITCH 9 LED
J6
LED - 10
SWITCH 10 LED
J7
LED - 12
SWITCH 12 LED
J8
LED - 14
SWITCH 14 LED
J9
LED – 15
SWITCH 15 LED