M0A21/M0A23 Series
May 06, 2022
Page
719
of 746
Rev 1.02
M0
A21
/M
0
A
2
3
SE
RIES
TEC
H
NICAL
RE
FEREN
C
E
M
ANUAL
DAC Status Register (DAC_STATUS)
Register
Offset
R/W
Description
Reset Value
DAC_STATUS
0x10
R/W
DAC Status Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
Reserved
BUSY
7
6
5
4
3
2
1
0
Reserved
DMAUDR
FINISH
Bits Description
[31:9]
Reserved
Reserved.
[8]
BUSY
DAC Busy Flag (Read Only)
0 = DAC is ready for next conversion.
1 = DAC is busy in conversion.
This is read only bit.
[7:2]
Reserved
Reserved.
[1]
DMAUDR
DMA Under Run Interrupt Flag
0 = No DMA under-run error condition occurred.
1 = DMA under-run error condition occurred.
User writes 1 to clear this bit.
[0]
FINISH
DAC Conversion Complete Finish Flag
0 = DAC is in conversion state.
1 = DAC conversion finish.
This bit set to 1 when conversion time counter counts to SETTLET. It is cleared to 0 when DAC starts a new
conversion. User writes 1 to clear this bit to 0.