M0A21/M0A23 Series
May 06, 2022
Page
302
of 746
Rev 1.02
M0
A21
/M
0
A
2
3
SE
RIES
TEC
H
NICAL
RE
FEREN
C
E
M
ANUAL
TM0 pin
TIMR0 INTRGEN
TIMR0 EXTCNTEN
TIMR0 CNT
0
1
2
3
99
100
TIMR1 INTR_TMR_TRG
TIMR0 CMPDAT
100
0
TIMR1 CNT
0
1
2
998
999
TIMR1 CAPDAT
999
TIMR1 CAPIF
Figure 6.7-7 Inter-Timer Trigger Capture Timing
User must clear Timer1/3 CAPIF if user wants to use the second inter-timer trigger function.
Capture Single Measure Mode
When user sets CAPEN (TIMERx_EXTCTL[3]) = 1 and CASIGMEN(TIMERx_EXTCTL[20]) = 1, Timer
will enter Single Meaure Mode. User can use timer to measure full period or half period. When user
writes one to SIGST (TIMERx_EXTCTL[21]), timer will start to measure TMx_EXT. When timer detects
edge finish, SIGST will be auto cleared by hardware and the measured value will be uploaded to Timer
Capture Data Register. User can write one to SIGST to trigger timer measure again.