M0A21/M0A23 Series
May 06, 2022
Page
312
of 746
Rev 1.02
M0
A21
/M
0
A
2
3
SE
RIES
TEC
H
NICAL
RE
FEREN
C
E
M
ANUAL
Timer Capture Data Register (TIMERx_CAP)
Register
Offset
R/W
Description
Reset Value
TIMER0_CAP
T0x10
R
Timer0 Capture Data Register
0x0000_0000
TIMER1_CAP
T0x30
R
Timer1 Capture Data Register
0x0000_0000
TIMER2_CAP
T0x10
R
Timer2 Capture Data Register
0x0000_0000
TIMER3_CAP
T0x30
R
Timer3 Capture Data Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
CAPDAT
15
14
13
12
11
10
9
8
CAPDAT
7
6
5
4
3
2
1
0
CAPDAT
Bits
Description
[31:24]
Reserved
Reserved.
[23:0]
CAPDAT
Timer Capture Data Register
When CAPEN (TIMERx_EXTCTL[3]) bit is set, and a transition on TMx_EXT pin matched the CAPEDGE
(TIMERx_EXTCTL[14:12]) setting, CAPIF (TIMERx_EINTSTS[0]) will set to 1 and the current timer counter
value CNT (TIMERx_CNT[23:0]) will be auto-loaded into this CAPDAT field.