TA600032-EN0/0
- 58 -
5.2.4.3
Interrupt clear
Each interrupt bit of "Status" (MSTS) can be cleared by "Local CPU"
.
Operation
command
Symbol
Description
20h
CCAR
Clear "Device setting change error" (MSTS.IEAR) interrupt.
For details, see "6.8.2.1
21h
CCWR
Clear "Port data write error" (MSTS.IWER) interrupt.
For details, see "6.8.2.2 Port data write error".
22h
CCTM
Clear "Port data write processing error" (MSTS.ITER) interrupt.
For details, see "6.8.2.3
Port data write processing error".
23h
CCBC
Clear "Broadcast command reception event" (MSTS.IBCS) interrupt.
For details, see "6.8.2.5
Broadcast command reception event".
24h
CCTC
Clear "Relative time management counter digit overflow event" (MSTS.ITCO) interrupt.
For details, see "6.8.2.6
Relative time management counter digit overflow event".
25h
CCPV
Clear "Port change interrupt information acquisition failure event" (MSTS.IPOV) interrupt.
For details, see "6.8.2.7
Port change interrupt information acquisition failure event".
26h
CCTT
Clear "Motionnet
®
communication timeout event" (MSTS.ITOT) interrupt.
For details, see "6.8.2.8 Motionnet
5.2.4.4
General-purpose one-shot operation
"General-purpose one-shot 0" signal (SHT0 pin) and "General-purpose one-shot 1" signal (SHT1 pin) can be output.
Operation
command
Symbol
Description
30h
CST0
Output "General-purpose one-shot 0" signal (SHT0 pin).
For details, see "6.4.1 'General-purpose one-shot 0' signal (SHT0 pin)".
31h
CST1
Output "General-purpose one-shot 1" signal (SHT1 pin).
For details, see "6.4.2 'General-purpose one-shot 1' signal (SHT1 pin)".