TA600032-EN0/0
- 59 -
5.2.5
Status (MSTS)
Interrupt factors of "G9006" and connection states of "Motionnet
®
" can be read.
There are 12 valid bits.
The size of "Status" (MSTS) is 2 bytes.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
EAER WRED TOUT BBSY SSBY ITOT IPOV ITCO IBCS IPTC ITER IWER IAER
Bit
Symbol
Description
0
IAER
The "Device setting change error" interrupt can be read.
0: No error has occurred.
1: An error has occurred. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.1
1
IWER
The "Port data write error" interrupt can be read.
0: No error has occurred.
1: An error has occurred. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.2 Port data write error".
2
ITER
The "Port data write processing error" interrupt can be read.
0: No error has occurred.
1: An error has occurred. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.3
Port data write processing error".
3
IPTC
When "Port change interrupt setting memory" or "RENV1.FDWA" or "RENV1.FUPA" is set, the "Port
change event" interrupt of the monitored "Local LSI" can be read.
0: No event has generated.
1: An event has generated. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.4
4
IBCS
When "RENV1.QBCS = 1" is set, the "Broadcast command reception event" interrupt can be read.
0: No event has generated.
1: An event has generated. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.5
Broadcast command reception event".
5
ITCO
When "RENV1.QTCO = 1" is set, the "Relative time management counter digit overflow event"
interrupt can be read.
0: No event has generated.
1: An event has generated. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.6
Relative time management counter digit overflow event".
6
IPOV
When "RENV1.QPOV = 1" is set, the "Port change interrupt information acquisition failure event"
interrupt can be read.
0: No event has generated.
1: An event has generated. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.7 Port change interrupt information acquisition failure event".
7
ITOT
When "RENV1.QTOT = 1" is set, the "Motionnet
®
communication timeout event" interrupt can be read.
0: No event has generated.
1: An event has generated. An "Interrupt request" signal (INT pin) can be output.
For details, see "6.8.2.8 Motionnet