TA600032-EN0/0
- 64 -
6.
Feature Description
This
chapter describes the functions of "G9006".
6.1
Reset
There are two ways to reset "G9006".
C a u t i o n
After turning on the power of "G9006", be sure to perform "Hardware reset" before starting to use.
6.1.1
Hardware reset
"Hardware reset" can be executed by the following procedures:
1.
Turn on the power.
2.
Input "RST = L level".
3.
Input "CLK" signal 8 cycles or more.
4.
Input "RST = H level".
5.
Input "CLK" signal 8 cycles or more.
by
6.1.2
Software reset
"Software reset" can be executed as follows.
1.
Write "CSREN" (01h) operation command from the "Local CPU".
2.
Write "CSRST" (00h) operation command from the "Local CPU".
"G9006" is reset by writing the "CSRST" (00h) operation command following writing of the "CSREN" (01h) operation command.
"G9006" is not reset by writing the "CSRST" (00h) operation command following writing other than the "CSREN" (01h) operation
command.
OFF
Power
RST
CLK
ON
Access
OK
Low
NG
High
8 cycles or more
8 cycles or more
High