TA600032-EN0/0
- 33 -
5.2.1.1
Writing control with address
When a "Write" control command with "Address" is output, the output data of the "MOSI" signals following the "Address"
becomes the "Write-in data".
"Write-in data" can be output continuously up to 32 bytes.
The "Local CPU" outputs "Write-in data" to "G9006" in synchronization with the falling edge of the "SCK" signal.
"G9006" inputs "Write-in data" from the "MOSI" signal in synchronization with the rising edge of the "SCK" signal.
5.2.1.2
Read control with address
When a "Read" control command with "Address" is output, the output data of the "MOSI" signals following the "Address"
becomes "Dummy data".
"Read-out data" can be input from the "MISO" signal in synchronization with the output of "Dummy data".
"Read-out data" can be input continuously without any restrictions.
"G9006" outputs "Read-out data" the "Local CPU" in synchronization with the falling edge of the "SCK" signal.
The "Local CPU" inputs "Read-out data" from the "MISO" signal in synchronization with the rising edge of the "SCK" signal.
SS
Write control command
SCK
MOSI
Address
Write-in data
MISO
D7
D6
D5
D4
D3
D2
D1
D0 D15 D14 D13 D12 D11 D10 D9
D8
C7
C6
C5
C4
C3
C2
C1
C0
A7
A6
A5
A4
A3
A2
A1
A0
Hi-Z
Hi-Z
Dummy data
SS
Read control command
SCK
MOSI
Address
Read-out data
MISO
D7
D6
D5
D4
D3
D2
D1
D0 D15 D14 D13 D12 D11 D10 D9
D8
C7
C6
C5
C4
C3
C2
C1
C0
A7
A6
A5
A4
A3
A2
A1
A0
Hi-Z
Hi-Z