NHDR
-
4xxxAHD user’s manual ver. 1.1
All rights reserved © AAT Holding S.A.
47
ALARMS
There are buttons in the bottom right corner:
-
Alarm
or
Motion
-
opens a separate action or detection settings window.
-
Copy
-
copies selected parameters of one camera to anothers.
-
Default
-
restores the default settings of this screen.
-
Apply
-
saves all settings.
7.2. Alarm inputs
The
IO
submenu contains settings for responding to changes in the status of alarm inputs in DVR and
Novus 2000 and 4000 series IP cameras.
The table columns are described below. Some columns may not be visible, to see them you need to
move the scroll bar at the bottom of the screen:
Alarm In
-
number of alarm input.
Local
means alarm input on the recorder,
IP CH
means alarm input
on IP camera.
Alarm type
-
specify the type of alarm input:
Normally
-
Open
-
high state activation,
Normally
-
Closed
-
low state activation, or
OFF
-
inactive.
Buzzer
-
duration time of sound alarm after detection (
Disable
,
10s
,
20s
,
40s
,
60s
).
Alarm Out
-
enable alarm output. It is possible to change alarm output status on the recorder
(
Local
-
>1
) or in Novus 2000 or 4000 series IP camera (eg.
IP K.1
-
>1
).
Latch Time
.
-
time of the alarm output duration:
10s
,
20s
,
40s
,
60s
.
Channel
-
switching on the video stream recording when the alarm input is activated (it depends on the
recording schedule settings). It is possible to set the recording of multiple cameras to an event from
a
single alarm input.
Post Recording
-
defines the time of active alarm after the alarm ends:
5s
,
10s
,
15s
,
20s
,
30s
,
1min
,
2min
,
5min
. It also specifies full screen display and alarm recording time.
Show Message
-
displays the icon on the screen when the alarm input is activated.
Send email
-
send an e
-
mail message when an alarm occurs. The camera image will be sent as
attachment. Requires e
-
mail configuration in the
Network / Email
menu.
Full screen
-
displays the camera image in full screen mode when the alarm input is activated.