54
NovoPort® IV
4.6.2
Pulse generator and external safety devices
No. Terminal Description
1
Overview of terminal assignment at the control unit
1
J
Plug base for radio receiver
2
E
Connector for antenna. When using an external antenna, the shield must be placed on
the left adjacent terminal (F).
3
F
Connector for external pulse generator (accessories, e.g. key switch or code keypad)
4
G
Connection for wicket door contact (accessory) or emergency stop
The drive is stopped or the start-up is suppressed via this input.
(see menu H)
5
G / H
Connection for photoelectric sensor LS2 (please refer to the connection points of the
photoelectric sensor manual for use of other photoelectric sensors)
6
I / H
Connection for 4-wire photoelectric sensor (e.g. LS5)
This input activates the automatic reversal of the drive during closing.
7
I
Connection for e.g. 24 V signal light (accessory)
Power supply 24 V DC, max. 100 mA (switched)
8
K
Connection for external, protectively insulated lighting or signal lamp (protection class
II, max. 500 W) (accessory)
9
F / I
Power supply 24 V DC max. 100 mA (permanent)
10
P
Connection for Mobility Module (accessory)
Information
In situations of increased requirements in terms of personal
protection, we recommend, in addition to the internal power limitation
of the drive, the installation of a 2-wire photoelectric sensor. The
installation of a 4-wire photoelectric sensor serves purely for the
protection of property. For further information on our range of
accessories, please refer to our sales literature or consult your
specialist dealer.
NOTICE
Before using the operator for the first time, it must be tested to make
sure that it is working properly and safely (see chapter Maintenance /
Checks, page 74).