NovoPort® IV
63
4.10.6 Menu H: STOP-A settings
1.
Select menu item “H”. After approximately 2 seconds, the display flashes and
shows the set value of the operating mode. The factory setting is “0”.
2.
If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C)
buttons.
4.11 TTZ guideline - Burglar resistance for garage doors
4.11.1 Enabling burglar resistance
To enable burglar resistance, proceed as follows:
1.
Turn the ball handle so that the pull cord sits in the ball handle's groove.
2.
Pull the ball handle off the pull cord as shown below.
Burglar resistance is now enabled.
Fig. 4-14
Enabling burglar resistance
Value Description
Remarks
0
Normal operation
Factory settings
1
Normal operation
with ventilation
settings*
Allows the ventilation of the garage. In this mode, the garage door is
approximately 10 cm wide open. To start up the ventilation setting, press the
second button on the hand transmitter or use a DuoControl/Signal 111
(accessories) setting* that must be programmed in Menu 2. The garage
door can be closed at any time using the hand transmitter. The garage door
closes automatically after 60 minutes.
2
Normal operation
with partial
opening*
In this mode, the garage door is approximately 1 m wide open. To start up
the partial opening, press the second button on the hand transmitter or use
a DuoControl/Signal 111 (accessories) setting* that must be programmed in
Menu 2.
Remarks:
* : The second button of the transmitter must be reset after changes in operating modes 1 or 2.
Value Description
Remarks
0
ENS-S 8200 connected to STOP-A input (terminal G)
1
Jumper or ENS-S 1000 connected to STOP-A input (terminal G)