35
Manual No. NT-0-350 - Rev. May 2021
NOVA Truck Lock
™
Standard Profile Manual
• If the control box is not a CB-11-A or B or C, skip step “a” below:
• If the control box is a CB-11-A or B or C perform step “a” below:
FIGURE BH
—
RIG SENSOR IN FORWARD POSITION
FIGURE BJ
—
RESTRAIN POSITION, HORN SOUNDING
2P. Test RESTRAIN Function (With RIG Sensor)
a. Interlocked equipment must be in position listed below:
Part Number: CB-11-A
Door must be closed
OR
Part Number: CB-11-B
Door could be opened or closed
OR
Part Number: CB-11-C
Leveler must be stored
b. There should be no object activating RIG sensor.
c. Depress “RESTRAIN” (#1 button).
d. Verify the vertical barrier has risen.
e.
Verify the RED light on the control box is flashing.
f. Verify the HORN is sounding at 1 second intervals.
g.
Verify the outside RED light is flashing.
h. Temporarily activate RIG sensor until the end of this test.
Verify Part Number located on door inside control box
INSTALLATION INSTRUCTIONS
RESTRAINT POSITION
FIGURE BI
—
RESTRAIN OPERATION
RED LIGHT
FLASHING
Summary of Contents for Standard Profile Truck Lock Series