42
Manual No. NT-0-350 - Rev. May 2021
NOVA Truck Lock
™
Standard Profile Manual
FAULT from RESTRAINING State (Manual)
Ram bar cannot block the RIG. This could be due to a
RIG that is located too far toward the rear axle, bent,
obstructed or missing. Activation handle is unable to
move into RESTRAIN position. Inside light is flashing
RED and HORN is pulsing, alerting the forklift operator
that the trailer is not captured. Outside light is flashing
RED alerting the truck driver not to move. See Figure
BV.
FIGURE BV
—
FAULT STATE
If the trailer is parked firmly against the dock bumpers
proceed to HORN OVER-RIDE. If not, return activation
handle to RELEASE position to clear the fault,
have trailer back up and repeat Restraint LOCKING
procedure.
HORN OVER-RIDE (Manual)
If HORN sounds and RED light is on after attempting
to RESTRAIN the RIG, the trailer may not be
serviceable. Ensure dock leveler is in the stored
position. Secure trailer by alternate means. Depress
the “HORN OVER-RIDE” button (0) on the key pad,
enter default over-ride code 5528 then press the
“ENTER” button. Inside RED and GREEN lights are
flashing; outside light is flashing RED only. Position
dock leveler to service trailer and proceed with
caution.
DANGER
DANGER
Before activating “HORN OVER-RIDE”, ensure
that dock leveler is in stored position and secure
trailer by other means.
HORN OVER-RIDE RESET
Ensure dock leveler is in the stored position.
Unsecure the trailer. Depress the “HORN OVER-
RIDE” button (0) on the key pad, enter default over-
ride code 5528 then press the “ENTER” button.
FIGURE BW
—
HORN OVER-RIDE STATE
OPERATING PROCEDURES
5528 = Default over-ride code. The default over-ride code can be changed.
RED LIGHT
FLASHING
RED AND GREEN
LIGHTS
FLASHING
Summary of Contents for Standard Profile Truck Lock Series
Page 2: ......