61
Manual No. NT-0-350 - Rev. May 2021
NOVA Truck Lock
™
Standard Profile Manual
3. Ensure restraint is in the unlocked position.
4. Remove console cover from console.
5. Test Limit Switch 1.
a. Verify (1) is shown below input 1.
b. Remove connector from limit switch.
i. Control box will alarm.
c. Verify (0) is shown below input 1.
d. Reconnect connector to limit switch.
i. Control box will stop alarming.
e. Verify (1) is shown below input 1.
If limit switch did not respond accordingly as stated above, replace limit switch. Part Number: 06-0-013.
6. Test Limit Switch 2.
a. Verify (1) is shown below input 2.
b. Depress limit switch 2.
i. Control box will alarm.
c. Verify (1) is shown below input 2.
d. Release limit switch 2.
e. Verify (0) is shown below input 2.
If limit switch did not respond accordingly as stated above, replace limit switch. Part Number: 06-0-013.
7. Reinstall console cover to console.
8. Exiting Maintenance Mode on the Control Box.
Key Point: This procedure can be done on any maintenance display.
a. Depress the “HORN OVER-RIDE” button (#0 button).
b.
The RED light, on the control box, will start flashing if the GREEN light was flashing or remain a constant
RED. This is normal to notify the end user that they are about to enter a new mode.
c. Enter the Maintenance code, 28252, and then press “ENTER”.
i. If the wrong code was entered, the “Wrong PW: Reenter Or wait” display will appear. On this display,
repeat steps 3a through 3c to enter maintenance mode.
ii. Or if no further input is completed within 30 seconds, the “Wrong PW: Reenter Or wait” display will
clear, the screen will return to last display prior to entering maintenance mode.
TROUBLESHOOTING
Summary of Contents for Standard Profile Truck Lock Series
Page 2: ......