Page 76 of 536
Chapter 8 – Installing a new system
553-3121-210
Standard 3.0
January 1999
10
Connect the SDI interfaces on the SSC card to the appropriate SDI
port cables. If required, connect the ethernet cable to the ethernet
interface connector in the main cabinet. Refer to
Installing and connecting SDI and Ethernet ports” on page 125
.
Make sure the baud rate and device option settings are properly set.
If the equipment operates in DTE mode, make sure that the A0601396
or A0601397 Modem eliminator is installed.
Connect communication equipment such as TTY terminals and
modems to the SDI cables.
11
Start up and test the system as described in
“Chapter 16 – Starting up and testing the system” on page 139
.
Check all connections and make sure that the circuit cards are properly
installed.
Make sure that the circuit breaker in each cabinet is set to ON.
If the system is equipped with one or more expansion cabinets, check
the fiber related LEDs on the SSC card.
•
The LED for the Expansion Daughterboard should be green.
•
If it is red (disabled indication);
Load overlay program 135 and enter ENL FL1 for first
expansion cabinet, or ENL FL2 for the second expansion
cabinet.
•
If the LED is yellow (fault indication):
Check the fiber optic cable to make sure that it is properly
connected and not damaged.
12
Connect the M2616 or M2008 administration and maintenance
telephone equipped with a display. Configure it as Model 99.
Refer to
“Chapter 17 – Connecting the telephones and attendant
.
Make sure that it is activated as a model 99.
Summary of Contents for Meridian Meridian 1
Page 3: ...553 3121 210 Standard 3 0 January 1999 ...
Page 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Page 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Page 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Page 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Page 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Page 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Page 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Page 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Page 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...