Chapter 13 – Installing the circuit cards
Page 117 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
NTMW44 4-port Universal Trunk Card
The NTMW07 4 Port Universal Trunk Card supports 4 universal analog trunk
ports (loop and ground start).
Procedure 10
4UT installation
1
Verify jumper strap settings (see
2
Insert the NTMW44 card in its assigned slot.
3
Connect an NE-A25B type 25 pair cable from the connector on the
faceplate of the NTMW44 to the cross-connect terminal.
4
Configure and enable the card using overlay programs 10 for line
ports, 14 for trunks and 32.
5
Set J1 jumper to 2,3 to disable Power Fail Transfer.
—————————— End of Procedure ——————————
Summary of Contents for Meridian Meridian 1
Page 3: ...553 3121 210 Standard 3 0 January 1999 ...
Page 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Page 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Page 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Page 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Page 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Page 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Page 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Page 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Page 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...