Chapter 24 – Changing pre-programmed data
Page 425 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
Changing or removing the pre-programmed night number
The default value of the night number is listed in
Pre-programmed data” on page 363
.
To change or remove the night number, use LD 15.
LD 15
REQ
CHG
CHG = Change
TYPE
CDB
CDB = Customer Data Block
CUST
x
“x” = Customer number
NIT1
bbbb, or Xaaaa
“bbbb” = the new extension number (DN)
Or
“aaaa” = the current night number
(the night number is now removed).