Procedure 83
Accessing the system from a system terminal
1
Press the return key.
•
If the response is
OVL111 nn IDLE or OVL111 nn BKGD
you are ready to log into the system. Go to Step 2.
•
If the response is
OVL000 >
you are already logged into the system. Go to Step 4.
Responses may vary with different Background Terminal
packages.
2
Enter
LOGI
then press the return key.
The normal response is
PASS?
If there is any other response, see the
Option 11C Compact Software
Guide.
3
Enter either the level 1 or level 2 password and press the return key.
If the password is correct, the system responds with the prompt
>
4
Enter
LD xx
“xx” represents the number of the program.
5
Perform tasks.
6
End the program by entering
****
7
End the log in session with
LOGO
—————————— End of Procedure ——————————
Summary of Contents for Meridian Meridian 1
Page 3: ...553 3121 210 Standard 3 0 January 1999 ...
Page 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Page 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Page 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Page 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Page 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Page 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Page 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Page 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Page 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...