Page 450 of 536
Chapter 25 — Fault locating and clearing
553-3121-210
Standard 3.0
January 1999
Table 58
Programs used in Midnight and Background Routines
Overlay Loader
This program locates, loads, and checks software programs. It automatically
activates the Midnight and Background Routines. You can load programs
manually by entering commands through the system terminal or maintenance
telephone. Once the program is loaded, you see the program mnemonic (such
as TRK for Trunk Diagnostic) on the system terminal.
Overload Monitor
The volume of system messages is continuously monitored by the system. If
too many error messages are detected from a line or trunk card, the system
activates the Overload Monitor program. The Overload Monitor disables the
faulty card and generates system messages with the mnemonic OVD.
Resident Trunk Diagnostic
This program automatically monitors all trunk calls and records apparent
faults on each trunk. If the number of faults on a trunk exceeds the threshold
for that trunk, the program generates a system message identifying the trunk
and the type of fault.
Program number
Program function
LD 30
Network and Signaling Diagnostic
LD 34
Tone and Digit Switch and Digitone Receiver
LD 36
Trunk Diagnostic 1
LD 38
Conference Circuit Diagnostic
LD 40
Call Detail Recording Diagnostic
LD 41
Trunk Diagnostic 2
LD 43 (Midnight only)
Data Dump
LD 44
Software Audit
LD 46
Multifrequency Sender Diagnostic
LD 60 (Midnight only)
Digital Trunk Interface Diagnostic
LD 61 (Midnight only)
Message Waiting Lamp
LD 135
Common Equipment Diagnostic
LD 137
Input/Output Diagnostic
Summary of Contents for Meridian Meridian 1
Page 3: ...553 3121 210 Standard 3 0 January 1999 ...
Page 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Page 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Page 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Page 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Page 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Page 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Page 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Page 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Page 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...