JAA63051-R.3689.A
- A41 ・ AF-S VR MC 105/2.8G -
Servo driving time
Servo driving time
(4) Inspection of lens-servo time
Select the servo
driving amount respectively. Each lens-servo drive time must be within the standard.
Caution
:
If the MF ring is rotated during inspections, the waveform shows an abnormal value. Do NOT touch
the MF ring during inspections. Make inspections at the 5 positions as below.
Lens inclination
Position of index window
Horizontal
Up, right and left
Front lens group 90° upward
Front lens group 90° downward
(Lens position in inspecting)
E terminal
H terminal
E terminal
H terminal
●Oscilloscope setting
V/Div
:
5V
Coupling
:
DC
Time/Div
:
20 m Sec
Trigger Mode
:
SGL (S)
Trigger Coupling
:
DC
Trigger Source
:
CH1
Trigger Position
:-
4 div
※
The waveforms of E and H terminals have the
forms for going up for start and going down for
start.