JAA63051-R.3689.A
- A10 ・ AF-S VR MC 105/2.8G -
CH1
CH2
● Oscilloscope setting
V/Div (ch1) :50 mV
V/Div (ch2) : 50 mV
Coupling : AC
Time/Div :5 m Sec
Trigger Mode :NORMAL
Trigger Coupling : AC
Trigger Source :CH1
Trigger Position :
+
4 div
Trigger Type :EDGE
Trigger Level : 0V
INPUT (ch1) :AC
INPUT (ch2) :AC
Standard:
Amplitude of all pulses/waveforms is 130 mV or more.
Note:
Check the waveform by moving the focus ring back and forth
from the infinity-end to the close-end positions entirely.
Amplitude
Fig. 1
③
In case large waveform-noise (as shown in Fig. 1) is detected, use the FILTER function.
How to set FILTER function (e.g. DL1540 manufactured by YOKOGAWA
)
1. Press the FILTER button.
2. Select “Smooth” of the menu on screen and turn it ON.
④
In case the amplitude is small, disassemble up to the stage
of the GMR sensor FPC unit. Then if the deformation is
detected in the MR head, correct the deform of the MR
head. On the other hand, if such correction is impossible
or no deformation is detected, replace the GMR sensor
FPC unit. (Fig.2)
Note: When adjustments are made, prevent the magnetic
surface and MR head from touching the magnetized
driver bit. Otherwise, the magnetic data may be
damaged.
GMR unit
MR head
Fig.2
Summary of Contents for AF-S VR Micro Nikkor 105mm/f2.8G
Page 13: ...JAA63051 R 3689 A D11 AF S VR MC 105 2 8G Focus index unit 83 3 GMR unit Focus index unit ...
Page 100: ...JAA63051 R 3689 A A76 AF S VR MC 105 2 8G Target chart Resolution chart ...
Page 107: ...JAA63051 R 3689 A F1 AF S VR MC 105 2 8G 外観図 Sketch drawings ...
Page 108: ...JAA63051 R 3689 A F2 AF S VR MC 105 2 8G 組立図 Structure of the Lens ...
Page 109: ...JAA63051 R 3689 A F3 AF S VR MC 105 2 8G ...
Page 110: ...JAA63051 R 3689 A F4 AF S VR MC 105 2 8G ...
Page 111: ...JAA63051 R 3689 A F5 AF S VR MC 105 2 8G ...
Page 112: ...JAA63051 R 3689 A F6 AF S VR MC 105 2 8G ...
Page 113: ...JAA63051 R 3689 A F7 AF S VR MC 105 2 8G ...