- A51 ・ AF-S 28-300mm f/3.5-5.6G ED VR -
JAA80851-R.3811.A
J11360
Cross line of gauge
Contact pin
Standard position of contact pin:
In relation to the cross lines, the apex of the contact pin must be positioned as below.
Within one-fourth of diameter sideways from the intersecting point.
Caution: To confirm the position of the contact pin, look straight at the each contact pin
horizontally from an anterior view.
A-contact pin
2. Check whether the position of the A-contact pin meets the standard or not.
In case the result meets the standard, go to the procedure 5.
In case the result is out of standard, go to the next procedure and adjust it.
Lock hole of bayonet
mount unit
Reference pin
Inspection of AF-contact pin position
Whenever the contact unit is removed, be sure to make this AF-contact pin inspection.
1. Mount the inspection tool (J11360) on the bayonet mount unit by fitting the reference pin of [J11360] in
the lock hole of the bayonet mount unit.