- A28 ・ AF-S 28-300mm f/3.5-5.6G ED VR -
JAA80851-R.3811.A
B1007
B1007
B501
TA-0011 (6×15)
TA-0001 (7×40)
Valley-fold
Bend the contact unit (B1007) slightly along the red dotted line joining "
△
" end-points to be folded
easier at a later stage.
•
Connect the FPC of the contact unit (B1007) to the connector of the main PCB (#1001).
Attach the tape [TA-0001 (7×40)] to the FPC of the main PCB (#1001).
•
•
Attach the tape [TA-0011 (6×15)] to the FPC of the SWM unit (B501) (only when the tape was removed
for replacement, because of defects, etc).
Bend the FPC of the SWM unit (B501) slightly to be folded easier at a later step.
•
•
Mountain-fold
Reference position for attachment
Wrap the tape around FPC once as shown.
FPC of [#1001]
Wrap the tape around the FPC.
User ID:uncf8224