5/8 - Safety instruc
ti
ons and user guide for automa
ti
c pool covers
This document is the property of AS POOL - of the NextPool group and cannot be reproduced or communicated without our authorisa
ti
on.
5
3
For the OPEN, remove the housing on the
motor side (remove the OPEN PVC cap, loosen the
composite cover from the OPEN Solar). Disconnect
wires 1, 2, 3, and 4 of the motor cable in order to
slide it completely towards the sha
ft
and remove
the unlocking ring.
4
For the BANC, remove the top cover and unscrew
the butterfly screw from the housing inside the
BANC Solar. Disconnect wires 1, 2, 3, and 4 of the
motor cable in order to slide it completely towards
the sha
ft
and remove the unlocking ring.
5
For the IMM'Box: remove the key between the
sha
ft
and the motor or remove the motor.
6
For the IMM'Ax: in the motor connec
ti
on box
located close to the pool, disconnect the end of
run stop wires and the power wires from the motor
cable in order to slide the motor cable completely
towards the sha
ft
. Remove the pin blocker to access
and li
ft
the unlocking pin.
7
Manually accompany the unrolling of the cover,
making sure that the motor cable does not get
entangled.
8
Lock the safety mechanisms.
When commissioning the roller, a new adjustment
of the motor end of run stops will be needed.
4. Maintenance advice
In the event of a malfunc
ti
on or a repair preven
ti
ng
the closure and the securing of the pool, take all
necessary measures to prevent the access to the pool
of children under 5 years old.
• AS POOL (ABRIBLUE) only distributes its technical
products via a network of pool professionals which
carries out the installa
ti
on and follow-up depending
on the speci
fi
ci
ti
es of the pool. AS POOL (ABRIBLUE)
does not communicate directly with the pool owners.
Have the automa
ti
c cover serviced by a swimming
pool professional (we recommend your swimming
pool installer whose details are on the cover of this
manual), who will be able to contact our technical
assistance department. All spare parts must be
original spare parts in order to maintain our guarantee
and the cover’s compliance with the standard.
• Carry out a complete revision of the cover once a year.
• Whenever used, the cover should be inspected to
identify damage that may compromise its correct
opera
ti
on. A professional will diagnose whether some
slats need to be replaced.
• Check that the upkeep advice is applied and that the
user carries out his checks regularly. Otherwise go over
them item by item.
• Check that the coupling nuts are
ti
ghtened, that the
stop ring and all the screws are present on the axis.
• Check that the electric connections are tight and
operate correctly. Make sure there is no humidity or
oxida
ti
on on the cover's electric contacts (terminals
in the box, box connections, contacts of the key
switch).
• Check the condition and the ageing of the locking
mechanisms and the bungee cords used to retain the
PVC slats. Check that the straps are
ti
ght on the axis.
• Check the correct opera
ti
on of the
fi
ltering system, the
over
fl
ow and the water level regulator.
• Carry out several rolling and unrolling tests to make
sure the cover is opera
ti
onal and especially to check
that the end of run stops are correctly placed.
• When the system does not respond, your installer can
secure the pool by uncoupling the cover roller and
manually unrolling the cover onto the pool before
locking the safety mechanisms on the pool cover. In
this situa
ti
on the pool cannot be used un
ti
l the cover
is repaired.
• Handling the uncoupling of the roller mechanism
should be read thoroughly before opera
ti
on, with the
installa
ti
on instruc
ti
ons.
1
Switch o
ff
the box.
2
Block the rota
ti
on of the sha
ft
while keeping the
slats rolled around.