19/36 - Installa
ti
on instruc
ti
ons for the IMM'Ax automa
ti
c immersed safety cover
19
Fig. 45
Ouv./Open
Ferm./CLose
Com. +24Vdc
3
3
4
4
Ouv./Open
Ferm./Close
Com. +24 V dc
- Have the electric connections made by a qualified
technician in compliance with current standards.
- Fix the transformer box in the technical room.
- Install the key switch so that the cover can be controlled
with a permanent view over the pool.
- Place the key switch cable gland towards the bo
tt
om.
- Turn the grey plate "OPEN. CLOSE." as required.
- All the connections and disconnections must be made
when the power is o
ff
.
5.1.1.1 Box
Fig. 44
- In the box, connect the 230 V power cable to the domino
to the le
ft
of the terminals respec
ti
ng the " ", "L" and "N"
symbols.
- In the box, connect the motor power wires of the
connecting cable to the "RED" and "BLACK" terminals
taking care to respect the colours of the motor cable wires.
- In the box, connect the motor sensor wires of the
connec
ti
ng cable to terminals 1, 2 and 3 marked "WHITE"
"BROWN" and "BLUE" taking care to respect the colours of
the motor cable wires.
- In the box, connect the key switch wires to terminals 4, 5
and 6 marked "COMMON", "OPEN" and "CLOSE".
- Connect the treatment device to terminals 7 or 8 and 9
marked "NO", "NC" and "COMMON" if you chose to use
this func
ti
on.
5.1.1.2 Key switch
Fig. 45
In the key switch connect:
- the wire connected to "COMMON" on the terminals
marked "3"
- a shunt/bridge between the two "3" terminals
- the wire connected to "OPEN" on one of the terminals
marked "4"
- the wire connected to "CLOSE" on the other "4" terminal.
5.1.1.3 Connec
ti
on box
Fig. 46
- Plan M27 or M32 cable glands.
- In the connection box, connect the power and sensor
wires strictly respec
ti
ng the colour codes "RED", "BLACK",
"WHITE", "BROWN", and "BLUE" on the box card and the
colours of the motor cable wires.
- Use the dominoes provided for these connec
ti
ons.
- When the cover is installed and the opera
ti
ng tests are
complete, fill the connection box with sealing gel to
limit the oxida
ti
on of the connec
ti
ons which may cause
malfunc
ti
ons.
- The connec
ti
on box must be 50 cm outside of the volume 0
(see
fi
g. 1) and accessible at any
ti
me.
Fig. 46
IP X6 minimum
M
Marron
Marron
Bleu
Bleu
Blanc
Blanc
Rouge
Rouge
Noir
Noir
IP X6 minimum
Black
Black
Red
Red
Blue
Blue
Brown
Brown
White
White