Installa
ti
on instruc
ti
ons for the IMM'Ax automa
ti
c immersed safety cover - 26/36
26
Ouv./Open
Ferm./CLose
Com. +24Vdc
3
3
4
4
Com. +24 V dc
Ouv./Open
Ferm./Close
3
3
4
4
Fig. 62
- Connect the 230 V power cable to the terminal respec
ti
ng
the "earth", "N" and "P" symbols.
- Connect the motor power wires of the connec
ti
ng cable to
the "+" and "-" terminals.
- Connect the 4 connec
ti
ng wires for the external sensor to
terminals 1, 2, 3 and 4.
- Connect the treatment device to terminals 5 for the
common, 6 NO or 7 NC if you chose to use this func
ti
on.
- Connect the key switch wires to the "C" common, "O" open
and "F" close terminals.
6.2.2 Key
switch
Fig. 62
- the wire connected to "COMMON" on the terminals
marked "3"
- a shunt/bridge between the two "3" terminals
- the wire connected to "OPEN" on one of the terminals
marked "4"
- the wire connected to "CLOSE" on the other "4" terminal.
6.2.3 Connec
ti
on box
Fig. 63
- Connect the external sensor by connec
ti
ng the two brown
wires together in the domino corresponding to wire 1, the
two blue wires in the domino corresponding to wire 2, one
of the black wires in the domino corresponding to wire 3
and the other with domino 4.
- -Connect the motor power wires strictly respec
ti
ng the
colour codes "Red" and Black".
- The connec
ti
on box must be 50 cm outside of the volume 0
(see
fi
g. 1) and accessible at any
ti
me.
M
Bleu
Bleu
Noir
Noir
1
2
3
4
Marron
Marron
Rouge
Noir
+
Fig. 63
Black
Blue
Blue
Brown
Brown
Black
Red
Black