11/36 - Installa
ti
on instruc
ti
ons for the IMM'Ax automa
ti
c immersed safety cover
11
Fig. 23
Fig. 24
Fig. 22
40mm mini
40mm
150mm
40mm
mini
mini
maxi
100mm maxi
40 mm min.
150 mm
max.
100 mm
max.
40 mm
min.
40 mm
min.
Fig. 22
- Place the beam into the boxes making sure that the end
of the beam can never have less than 4 cm on each box.
Fig. 23
- Slide the white cylindrical cabiclips of the bungee cords
into the groove in the beam.
- Thread the counterweights onto the bungee cords and
spread them evenly over the width of the pool.
- Check the length adjustment of the bungee cords so that
the counterweights are at least 5 cm from the bo
tt
om of
the pool when the cover is unrolled.
3.2.6 Installing the duckboards
- Carry out the electric connec
ti
ons, the cover assembly
and the end of stop adjustments before installing the
duckboards.
Fig. 24
- Assemble the duckboard walkway so that each
independent element weighs at least 10 Kg/part
(approx . 1 m²):
• Wooden duckboards are assembled side by side using
the cylindrical plugs,
• Aluminium duckboards are assembled by longitudinal
threading and are blocked using the headless screws,
• PVC duckboards are clipped together by striking the
side with a mallet and a wooden wedge when they are
laid side by side (from one end to the next).
• When the cover is installed and the opera
ti
ng tests
are complete,
fi
ll the connec
ti
on box with sealing gel to
limit the oxida
ti
on of the connec
ti
ons which may cause
malfunc
ti