The ice maker is fully automatic and will operate
in ambient temperatures as low as 0° F. To allow
operation at temperatures between 0° F and 32° F., the
ice maker has a heater on the solenoid water valve and
on the water line between the solenoid valve and the
ice maker.
When the freezer temperature of the refrigerator is low
enough, the ice maker opens the water solenoid valve
and fills the mold. The ice maker ejects the frozen ice
into a storage bin. As the storage bin fills, the ice raises
the shut-o
ff
arm until it turns o
ff
the ice maker. As you
use the ice and lower the ice level in the storage bin,
the shut-o
ff
arm also lowers. This turns the ice maker
ON and begins the process of making ice.
The ice maker operates on:
•
Cold potable water at a pressure of 15 psi - 125 psi
•
120 Volts AC: 108 VAC min. - 132 VAC max.
Optional Ice Maker
1. Make sure the ice maker AC power cord is plugged
into a receptacle.
2. Open the water shut o
ff
valve of the vehicle.
NOTE: Make sure that the ice maker arm can move freely
and does not touch the frozen foods in the freezer.
3. Push the ice maker arm down to the ON position.
CAUTION: If you operate the refrigerator without the
proper water supply, make sure the ice maker arm is up in
the OFF position.
4. Allow the freezer to cool enough and ice production
will begin to fill the storage bin.
NOTE: New plumbing connections and/or impurities in the
water supply line after winterizing can cause the first ice
to be discolored or have an odd flavor.
5. To stop the ice maker, push the ice maker arm up to
the OFF position.
ICE MAKER OPERATION:
Source(s): Norcold Owner’s Manual for 1200ACXX Models
Product(s): Norcold 12 Cu Ft 4 Door Refrigerator w/Ice Maker and Water Dispenser (Model: 1200IM, Newmar Part Number: 96051)
Norcold Refrigerator Operation (Model: N10 Series)
This article provides basic operation instructions for a Norcold Refrigerator with Ice Maker (Model: N10 Series).
Operating The Controls
•
Make sure the air flow in the lower intake vent,
through the refrigerator coils and condenser, and out
the upper exhaust vent is not blocked or decreased.
•
Make sure there are no combustible materials in or
around the refrigerator.
•
Make sure the DC voltage to the refrigerator is
12.0VDC
IGNITION AND START UP
Notice: For safety reasons,the refrigerators electronic
controls are designed such that while operating in the
LP GAS mode, the trial for ignition (maximum amount of
the time the gas valve and igniter can be left on without
a flame present) is limited to 30 seconds. When starting
the refrigerator for the first time, after storage, or after
replacing the propane gas tank, the propane gas supply
lines can have air in them.
Due to air in the gas supply lines, the burner may not
ignite within the 30 second time limit. In the event this
should happen the gas valve and igniter outputs will be
turned o
ff
, the LP Gas mode will be “locked out”, and the
appropriate fault code will be shown in the display.
The gas lock out condition can be reset by powering
the refrigerator OFF and then back ON, at which time, a
new 30 second trial for ignition will commence. It may be
necessary to repeat this procedure several times before
expelling all the air from the LP gas supply line. If after
repeated attempts, a flame is not established, stop and
consult your local dealer or Authorized Norcold Service
Center.
AIR IN THE PROPANE GAS SUPPLY