© 2020 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
21
SAFETY
The alarm operates in seven separate modes that will be
identified in this section.
Modes
Mode
LED
Audible Alarm
Power O
ff
O
ff
O
ff
Normal Stand By
Green
O
ff
Alarm
Red
Alarm
Test
Red
Alarm
Silence/Stabilization
Flashing Red
O
ff
Fault
Yellow
Chirp every 30 seconds
End-of-Life
Flashing Yellow
Chirp every 30 seconds
•
A flashing LED blinks once every second
•
An audible alarm in “fault slate” chirps once every 30
seconds
•
An audible alarm in “alarm state” chirps 4 times every
5 seconds
This mode indicates that there is insu
ffi
cient power
provided to the alarm. The LED and button will not function
in this mode. Su
ffi
cient power must be provided to the
alarm to exit this mode.
POWER OFF MODE
This mode indicates that the alarm is stabilizing for the first
3 minutes after power up or after the Reset Function was
initiated. In this mode the LED will be flashing Red. The
audible and the Test/Reset button function will be o
ff
. This
mode will be exited after 3 minutes. If gas concentrations
are still high after the 3 minutes, the previous alarm will
reactivate.
This mode indicates that a fault has been detected that
compromises the alarm function. This mode will be exited
automatically when the fault is cleared. If the fault persists,
the alarm is not functioning properly and must be replaced
to ensure your safety in the area. During this mode, the
LED will be Yellow and the audible alarm will chirp every 30
seconds.
Note: Unit must be powered for three minutes before test
can be performed.
SILENCE / STABILIZATION MODE
FAULT MODE
This mode indicates that a gas concentration is
continuously monitored. It also indicates that a gas
concentration is at a safe level. In this mode the LED
indicator will be Green. The Test function for the Test/Reset
button will be active.
This mode indicates that a gas concentration has achieved
unsafe levels. In this mode the LED will be Red. The LP
concentration is unsafe the Propane indicator will be lit. In
this mode the audible indicator will signal an alarm, and the
Reset function of the Test/Reset button will be active. This
mode will be exited automatically when LP concentrations
fall below 500 ppm for greater than 10 seconds.
This mode indicates that the Test function of the Test/Reset
button was initiated. In this mode, the LED will be Red, and
the audible indicator will signal an alarm. The Test/Rest
button will not function during this mode. This mode will be
exited automatically within 10 seconds.
The Test/Rest button is used to verify proper alarm
operation. Executing the test function sounds the alarm and
lights up the LED. The test will sound the alarm twice, with
4 “beeps” in 1 second followed by 5 seconds of silence. By
pressing the button, you can verify that the alarm sounds
and that the LED functions properly. The alarm is internally
monitored while powered to ensure proper operation and
to detect faults.
NORMAL STAND BY MODE
ALARM MODE
TEST MODE
Test Alarm operation after vehicle has been in storage,
before each trip, and at least once per week during use.
IMPORTANT
!
The Detector will operate in end-of-life mode after the
Detector has been powered for 7 years +/- 128 days. This
represents the operating life of the sensor used to detect
LP gas. After 7 years, the sensor is no longer reliable and
the Detector must be replaced. Once end-of-life mode
has been entered, it is permanent, even after a power out
cycle. If the reset/test button is pressed during end-of-
life mode, the audible alarm will be silenced for 12 hours
before being automatically reactivated. The LED will be
flashing Yellow. The audible alarm will chirp every 30
seconds.
END OF LIFE MODE
Source(s): Atwood Model LP User’s Manual and Installation Instructions
Product(s): This source is associated with more than one product. Refer
to Newgle for more information about the product(s) o
ff
ered for your
coach’s model year.