HVAC
•
ARROW — Page jump back to the Now/Status Page
•
SET CURRENT TIME — Use “HR” & “MIN” buttons to
set the time of day
•
SET PROG — Page jump to the “DAY/NIGHT” setup
SETUP DAY/NIGHT PAGE
•
ARROW—Page jump back to the Now/Status Page
Mode Description
OFF-OFF MODE
•
Displays “OFF” mode in a zone
COOL-COOL MODE
•
In the COOL mode the system will cycle the
compressor ON and OFF based on the room air
temperature and the temperature set-point on the
LCD. When the system calls for cooling there will be
a delay of approximately 2 minutes. During this delay,
the hour glass icon will be displayed in the LCD. In
auto fan, the fan will turn ON first followed by the
compressor in approximately 15 seconds.
•
In COOL mode there are (4) fan speed selections:
LOW / MED / HIGH: The fan operates continuously at
low speed. The compressor only cycles ON and OFF.
•
AUTO: When auto fan is selected the fan speed
will vary depending on the di
ff
erence between the
temperature set-point and the room temperature.
In auto fan the compressor and the fan will both
cycle ON and OFF. The compressor shuts OFF first
followed by the fan in approximately 15 seconds. For
more information on auto fan, see section, “A. Auto
Fan.”
HEAT PUMP—HEAT PUMP MODE
•
In the HP mode the system will cycle the compressor
ON and OFF based on the room air temperature
and the temperature set-point on the LCD. When
the system calls for heating there will be a delay of
approximately 2 minutes. During this delay, the hour
glass icon will be displayed on the LCD. In auto fan,
the compressor will turn ON first followed by the fan
in approximately 15 seconds.
•
In HP mode there are (4) fan speed selections: LOW
/ MED / HIGH: The fan operates continuously at low
speed. The compressor only cycles ON and OFF.
•
AUTO: When auto fan is selected the fan speed
will vary depending on the di
ff
erence between the
temperature set-point and the room temperature. In
auto fan the compressor and fan will cycle ON and
OFF with the thermostat. The compressor shuts OFF
first followed by the fan in approximately 15 seconds.
ROOM SELECTION
There are 1-3 rooms to choose from depending on the
floor plan, they are:
•
LVRM — Selecting this will display the current Living
Room settings
•
KIT — Selecting this will display the current
“KITCHEN” settings
•
BDRM — Selecting this will display the current “BED
ROOM” settings
INDIVIDUAL ROOM SETTINGS
•
MODE — Selects: OFF, AUTO, COOL, HEAT PUMP,
FURNACE, or FAN
•
FAN — Selects: AUTO, LOW, MED, OR HIGH
•
TEMPERATURE — Use UP/DN Triangles to adjust
room temperature
STATUS DISPLAY
•
SET TEMPERATURE — Target temperature for the
room
•
HOUR GLASS — System is waiting on the room’s roof
top compressor to turn
•
PROG O-RIDE — The “DAY/NIGHT” settings are
being overridden by “HOLD”
•
FIRE FLAME — Represents the furnace is turned on
•
SNOWFLAKE — Indicates the air conditioner
compressor is turned on
•
RED WAVES — Indicates the heat pump compressor
is turned on
SETUP TIME PAGE
•
DAY—Displays the DAY setup for the room selected
•
NIGHT—Displays the NIGHT setup for the room
selected
•
On a per room basis the DAY, NIGHT, TIME, TEMP,
MODE, & FAN can be setup for a “RUN PROG”
schedule. The individual rooms settings are changed
to “DAY/NIGHT” setting when the time entered for
the room is the time of day.
•
Example — DAY/LVRM settings are 8:00AM, COOL,
FAN AUTO, 70 F. When the time of day is 8:00AM
on the LVRM “NOW/STATUS” page all settings will
change to the for mentioned.
Note: The “LVRM” mode “COOL & HEAT”