59
Warning:
when installing the feeder on the equipment, make sure there is no foreign matter on
the feeder fixed plate, and make the bottom surface of the feeder fully fit with the fixed plate. The handle is the main way
to lock the feeder, so pls pay attention to protect this part. (
Note:
Don’t move the feeder while the equipment is running,
or it may cause collision problem.)
13.3.1 Nozzle
In order to ensure the placement accuracy
,
please select nozzles according to the shape and size of components
Table 1-1 Nozzle
Type
Regular Regular Regular Regular Regular Regular Regular Regular
Model
CN030 CN040 CN065 CN100 CN140 CN220 CN400 CN750
Illust
ration
Extern
al
Diame
ter
0.6mm 0.8mm 1.0mm 1.8MM 2.0mm 3.6mm 5.0mm 9.0mm
Inner
Diame
ter
0.3mm 0.4mm 0.7mm 1.0MM 1.4mm 2.2mm
4mm
7.5mm