50
10.
Nozzle Height Set Zero
10.3 Basic Configuration
Default placement speed:
The placement speed of the processing interface adopts the default speed configured by the
system
Fiducial camera brightness and IC camera brightness:
the default value of camera brightness when factory setting
:
the
Warning: This function is required to initialize after the height zero calibration of the
placement head, this operation should be operated with caution, there is a risk that
the equipment cannot be used, it is recommended that changes be made under the
guidance of the manufacturer's engineers!
Warning: This function is necessary for zero calibration of the nozzle height (very
important) after new installation or re-measurement of the upper and lower motors
or upper and lower conveyor synchronous belts, otherwise an accident will occur by
hitting the nozzle. This operation should be done with caution, there is a risk of
rendering the equipment unusable and it is recommended that changes be made
under the guidance of the manufacturer's engineers!