35
Batch processing pick up position and height: please select one stack to start setting (default start from the first assigned
stack), at the same time, a real-time image will be showed as right side. Please set the red cross to the component center
( generally if the feeder is in off condition, red cross will be at the edge of feeder’s tape cover ), click “save and next” until
all be set well and there will be beep sound as a warning, then click “save and exit”to finish it. After that, you can select any
feeder’s pick position as a test. While setting the pick position, the function of “Feeder open”/ “Feeder close” can help
setting the cross position more conveniently.
(
4
)
Footprint library: The component’s information is saved in the footprint library,including name, length, width,
height, edge, pitch etc. Please note the detailed information for the IC is necessary. Press “Add” button to add a new
footprint into the library; For footprints not required, please directly select them and press “Delete” button to move them.
Save the setting before exit
7.2 Feeder Setting
Select one feeder, tick “Apply”, then its related info can be edited such as feeder exchange, feeder, nozzle, IC tray feeder etc.
The setting sequence for them should be: Feeder (or IC tray feeder)→ Feeder basic information→ Nozzle. P. S.: 1) For
feeders 1-66, the IC tray feeder is in disabled condition. 2) Feeder exchange depends on application condition, if the tape
reel was installed on wrong feeder, you can directly use feeder exchange to solve it.
(
1
)
IC tray feeder info
It is used to set tray package component’s pick position.