49
7. Automatic calibration
Nozzle Position View:
View the position of nozzles 1-8 in the center of the front IC camera. Click this button then 1-8
nozzles automatically perform actions and are displayed in this screen.
Automatic nozzle positioning:
The new version of the device enables automatic positioning of the nozzle with the front IC
camera.
Left and right Mark camera positioning:
this function is currently under development.
Front and Back IC camera angle:
the camera may have angle when the device is installed, this function can automatically
measure the angle of front and back IC camera to improve the placement accuracy. Click this button, nozzle 1 take mark
point and action, click return, the data of automatic measurement will be synchronized to the initial angle of front and rear
IC camera in the right base configuration
Automatic calibration interface
8. XY Linear Encoder Initialize
9. Mounting Head Linear Encoder Initialize
Warning: This function is required to initialize when the magnetic grid is newly
installed or has mechanical changes, this operation should be operated with caution,
there is a risk that the equipment cannot be used, it is recommended that changes
be made under the guidance of the manufacturer's engineers!