52
(
1
)
Feeder No.1-No.66
: after loading tape reel on feeder, click the feeder to test its feeding function.
(
2
)
Alarm light:
click it to test if the light could work correctly, the color should change from red, green to yellow by
sequence.
(
3
)
Buzzer:
click it to test if it works
(
4
)
XY initialize:
click to have XY back to zero
(
5
)
XY Move:
click this button to enter vision interface, the movement mode are optional, use the crosshair to move the
head.
(
6
)
Front IC Camera, Back IC Camera:
click to test the photograph function.
(
7
)
Right Fiducial Camera, Left Fiducial recognition Camera:
click to test the photograph function.
(
8
)
Head initialize:
head initialization can be executed before mounting
(
9
)
Nozzle Height Calib:
click to calibrate 8 nozzles’ initial heights
Step 1 Make sure the nozzle is installed, click “Nozzle Height Calib”
Step 2 Lock nozzle position above the rail (after selecting the position, for the alignment method you select the nozzle 1 and
save the position), select nozzle 1, and click on the keyboard to rise and fall button, to ensure that the nozzle just pressed to
the surface of rail, after the adjustment is complete, click save.
Calibrate other nozzles’ height in same way.
(
10
)
Head Home back:
click to move the head back to original left top position
(
11
)
Nozzle Replace:
click to replace nozzles, the head will move to its position for easier replacement.
(
12
)
Head Nozzle:
click to test rotation, suction, blow and moving down functions of nozzle NO.1-NO.8.
(
13
)
Width Initialize:
initialize the width of rails back to zero.
(
14
)
Width Set:
after the initialization of rails width, enter the expected width, click Width Set, the rails be widened
accordingly.
12. First trial and test
12.1 Program first dry run