48
done.
P.S. If the offset is overly beyond 0.1mm, please kindly contact NeoDen support team.
2. function introduction:
Mark Left Position
: to use the left camera align the round mark
Mark Right Position:
to use the right camera align the round mark
Exit:
exit without operation
Save:
save the date after operation
Brightness:
the brightness of mark camera can be adjusted accordingly.
(
Note: the other three functions: memory position, correction position, right Mark calibration. These functions
are currently under development.
)
3. Nozzle and IC Camera central position
Nozzle 1 front IC camera Central Position: click to align, nozzle 1 will move to front IC camera and take photos. Once
the photo is displayed, to align the central position of nozzle with white crosshair and save the data.(P.S. Once setup
the Nozzle 1 front IC Central Position, nozzle 2-8 central position will be changed based on nozzle 1.) Apply the same
operation for remaining nozzle 2 to nozzle 8.
Nozzle 1 back IC camera Central Position: click to align, nozzle 1 will move to back IC camera and take photos. Once
the photo is displayed, to align the central position of nozzle with red crosshair and save the data.
4.
Trash Box Position:
after Administration Login, click to align the position of trash box accordingly.
5.
Placement Head Reset Position:
after Administration Login, click to align the position of Placement Head Reset
accordingly.
6.
Exchange Nozzle Position:
after Administration Login, click to align the position of exchanging nozzles accordingly.