Program 12 to 15
Xen Topaz Programming Manual 62
P
ROGRAM
12: N
IGHT
M
ODE
S
ETUP
12-05: N
IGHT
M
ODE
G
ROUP
A
SSIGNMENT
FOR
T
RUNKS
Description
Use
Program 12-06 : Night Mode Group Assignment for Trunks
to assign a Day/Night Mode Group for
each trunk port.
Input Data
Default
Night Mode Groups 1 ~ 4 = 1
Conditions
None
Feature Cross Reference
♦
Night Service
Telephone Programming Instructions
To enter data for Program 12-06 (Night Mode Group Assignment for Trunks):
1. Enter the programming mode.
2. Enter 12 06
3. Enter the number of the item you want to program.
4. Select the Trunk port number to be programmed by pressing the FLASH or the VOLUME
▲
or VOL-
UME
▼
keys.
5. Enter data for the item you se HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Trunk Port Number
1-51
Night Mode Service Group Number
1-4
12-06-01TrkPrt1
Night Mode Grp 1
12-06-xx
xxxxx
This page left intentionally blank