Chapter 1 CCIS FEATURES
1-76
NWA-088654-001 Rev.1.0
94ch1003.fm
BUSY LAMP FIELD (BLF)-CCIS
Programming
• For BLF message sending office (Office A)
DESCRIPTION
DATA
Assign a Destination Point Code of each office
within the CCIS network, to the CCH number.
•
(1)
(2)
Y=0
00001-16367: DPC
00-63: CCH No.
Provide Busy Lamp Field (BLF)-CCIS to each
CCH number.
•
(1)
(2)
Y=30
00-63: CCH No.
0: To provide
Specify the sending BLF message via CCIS for
each station.
A maximum of 8 destinations (Destination No.
0-7) can be set for each station.
•
(1)
(2)
Y=30-37 Destination No. 0-7
X-XXXXXXXX: Station No.
0 : To send
1 : Not sent
Register the DPCs and their destination num-
ber for sending BLF message via CCIS.
A maximum of 8 destinations (Destination No.
0-7) can be set per system.
•
(1)
(2)
Y=08
0-7: Destination No. 0-7
assigned by CM12 Y=30-37
00001-16367: DPC
When the CCIS network adopts Open Num-
bering system, assign the access code and of-
fice number of own office to be added to the
station number for sending the BLF message.
•
(1)
(2)
Y=07
0
X-XXXX: Access Code + Originating Of-
fice No.
X: 0-9, A (*), B (#)
NOTE:
Amount of Access Code + Office
No. + Station No. must be no
more than 8 digits.
Specify whether the busy indication is provid-
ed on station base or extension base when the
Sub Line or Trunk Line is used on the
Multi-
line Terminal
.
NOTE:
The BLF indication is as follows:
(1)
(2)
269
0 : Station base
1 : Extension base
START
CMA8
CMA7
CM12
CM50
CM08
CM08>269
When Sub Line
is used
When Trunk
Line is used
0
My Line and Sub
Line
My Line
1
Sub Line
Not provided
END