Chapter 1 CCIS FEATURES
1-213
NWA-088654-001 Rev.1.0
94ch1006.fm
PAGING ACCESS-CCIS
To use the dual port mode, do the following programming (the following programming is not required only
when using the single port mode).
DESCRIPTION
DATA
Assign the station number connected to
PGD(2)-U10 ADP (CH2) to its associated
Physical Port number.
NOTE:
The setting of the Dual port mode is
required when using 2 paging equip-
ment on the PGD(2)-U10 ADP.
For details, refer to “Setting Meth-
od of Port number/Station number
in Dual port mode” in CM10 of the
Command Manual.
•
(1)
(2)
Y=00
XX YY ZZ: Physical Port No.
XX: 01-50: Unit No.
YY: 01-18: Slot No.
ZZ : 17-32: Circuit No.
FX-FXXXXXXXX: Station No.
For the station connected to PGD(2)-U10
ADP, set the Message Waiting/Stored Call
Record lamps not to be lit.
•
(1)
(2)
Y=03
X-XXXXXXXX: Station No.
1: Not provided
For the station connected to PGD(2)-U10
ADP, set the call history not to be stored when
answering a station call.
•
(1)
(2)
Y=41
X-XXXXXXXX: Station No.
1: Not stored
For the station connected to PGD(2)-U10
ADP, set the call history not to be stored when
handling an unanswered station call.
•
(1)
(2)
Y=49
X-XXXXXXXX: Station No.
1: Not stored
For the station connected to PGD(2)-U10
ADP, set the call history not to be stored when
answering a trunk call.
•
(1)
(2)
Y=60
X-XXXXXXXX: Station No.
1: Not stored
For the station connected to PGD(2)-U10
ADP, set the call history not to be stored when
handling an unanswered trunk call.
•
(1)
(2)
Y=61
X-XXXXXXXX: Station No.
1: Not stored
Assign the kind of PGD(2)-U10 station (CH2).
NOTE:
When this command is set, PGD(2)-
U10 needs to reset (Blade Reset or
pull out and reconnect the modular
connector of the Multiline Termi-
nal).
•
(1)
(2)
Y=65
X-XXXXXXXX: Station No.
1: Paging
START
CM10
CM13
CM12
A