![background image](http://html.mh-extra.com/html/nec/univerge-sv9300/univerge-sv9300_networking-manual_249030067.webp)
Chapter 1 CCIS FEATURES
1-53
NWA-088654-001 Rev.1.0
94ch1002.fm
CCIS BASIC PROGRAMMING
Example 2:
Inter-Tenant Connection for Incoming Call Termination
For the inter-tenant connection between Trunk C (Office A) and Station B (Office B), the data assignment
at Office B is as follows.
NOTE:
The inter-tenant restriction between Trunk B and Station B (CM63 Y=2) is ineffective.
Command Code
1st Data
2nd Data
CM63 Y=2
01 02
01: Tenant No. of Called Station
(Station B)
02: Tenant No. of Trunk (Trunk C)
1 : Allow
NO. 7 CCIS
TRUNK B
STA. B
TENANT NO.
TENANT NO.
OF TRUNK C: 01
OF STA. B: 02
TRUNK A
TRUNK C
OFFICE
B
OFFICE
A