Chapter 1 CCIS FEATURES
1-214
NWA-088654-001 Rev.1.0
94ch1006.fm
PAGING ACCESS-CCIS
DESCRIPTION
DATA
Assign the kind of paging to the PGD(2)-U10
station (CH2).
NOTE:
This data is valid when 2nd data: 1
(Paging) is assigned in CM12 Y=65.
•
(1)
(2)
Y=67
X-XXXXXXXX: Station No.
0 : Calling only (not using paging answer)
1 : Non-delay answer
2 : Non-delay and delay answer
3 : Ordinary station
Specify the Paging Zone to the PGD(2)-U10
station (CH2).
NOTE:
This data is valid when 2nd data: 1
(Paging) is assigned in CM12 Y=65.
•
(1)
(2)
Y=68
X-XXXXXXXX: Station No.
00-09
: Paging Zone No. assigned by
CM20 Y=0-3>A070-A079
NONE : No data
Assign the access code for Paging Answer.
•
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A070-A079: For Paging Answer
(Zone 0-9)
Assign the paging function to the PGD(2)-U10
ADP.
•
(1)
(2)
Y=00
XX Y
XX: 00-31: Relay Group No.
Y : 0-3: Circuit No. of PGD(2)-U10 ADP
02XX: Speaker Paging Start
XX : 00-09: Speaker Paging Zone 0-9
Associate the PGD(2)-U10 station number
with the Relay Group number.
•
(1)
(2)
Y=01
00-31: Relay Group No.
X-XXXXXXXX: PGD(2)-U10 Station No.
NONE
: No data
Provide the connection with Dual port mode to
the PGD(2)-U10 ADP (CH2).
•
(1)
(2)
Y=32
X-XXXXXXXX: Station No.
0 : To connect
1 : Not connected
Set the port mode of the PGD(2)-U10 ADP
(CH2) to Dual port mode.
•
(1)
(2)
Y=33
X-XXXXXXXX: Station No.
0 : Dual port mode
1 : Single port mode
A
CM12
CM20
CM44
CM13
BLADE RESET
BLADE RESET
B