Voice Mail Overflow
IntraMail System Guide
Chapter 2: Features
◆
185
2
Step 3
Set the over
fl
ow time (the interval calls will ring before over
fl
ow occurs).
3.1
0401 - DIL No Answer interval
- A DIL will over
fl
ow to the extension’s Subscriber Mailbox if not answered after this interval.
✔
By default, this interval is 15 seconds.
Programming Key Ring Over
fl
ow
Step 1
To set up Key Ring over
fl
ow during the day and at night:
1.1
1003 - Trunk Options: Direct Termination (Day)
- Press
CLEAR
to make the trunk a Key Ring trunk during the day and at night.
- Refer to the
DS1000/2000 Software Manual
for more.
✔
By default, during the day trunks are terminated to
Key Ring
(entered by pressing
CLEAR
).
1.2
1003 - Trunk Options: Day Over
fl
ow.
- Enter
Y
(9) to enable over
fl
ow for the trunk during the day.
- Refer to the
DS1000/2000 Software Manual
for more.
✔
By default, this option is
N
(6).
1.3
1003 - Trunk Options: Day Over
fl
ow Destination
- If you enable
Day Over
fl
ow
above, enter the IntraMail master number (
700
).
- Refer to the
DS1000/2000 Software Manual
for more.
- By default, this option is
300
.
Step 2
To set up Key Ring over
fl
ow only at night:
2.1
1003 - Trunk Options: Direct Termination (Night)
- Press
CLEAR
to make the trunk a Key Ring trunk when the system is in the night mode.
- Refer to the
DS1000/2000 Software Manual
for more.
✔
By default, at night trunks are terminated to
Key Ring
(entered by pressing
CLEAR
).
2.2
1003 - Trunk Options: Night Over
fl
ow.
- Enter
Y
(9) to enable Key Ring over
fl
ow when the system is in the night mode.
- Refer to the
DS1000/2000 Software Manual
for more.
✔
By default, this option is
N
(6).
2.3
1003 - Trunk Options: Night Over
fl
ow Destination
- If you enable
Night Over
fl
ow
above, enter the IntraMail master number (
700
).
- Refer to the
DS1000/2000 Software Manual
for more.
- By default, this option is
300
.
Step 3
Set the over
fl
ow time (the interval calls will Key Ring before over
fl
ow occurs).
3.1
0401 - Trunk Revert interval
- A Key Ring call will over
fl
ow to the IntraMail Automated Attendant if not answered after
this interval.
✔
By default, this interval is 15 seconds.
Operation
N/A