35
Figure 58
Note: Both power supply assemblies will be removed during this installation.
Note: Unplugging the cables will allow the power supplies to be removed from the
dispenser.
Note: The power supply
with
the Invenco Link installed is the power supply that is to be
associated with
Side A
of the Dispenser.
Note: The power supply assembly
without
the Invenco Link installed is to be associated
with
Side B
of the Dispenser.
6)
Uniquely label/mark each connection prior to disconnecting connections from the
power supplies so that they can easily be identified upon reinstallation.
7)
Unplug and label/mark the Yellow Cat5e Network Cable from the Invenco Link port
labeled “LAN1” annotated in Figure 59 below.