113
15)
Install the OPTIC heater mounting plate (497-0524577) by passing the cutout in the
plate past the plastic tooth in the pump wall. The bent tab on the top of the
bracket will slide behind that tooth to capture the bracket. Figure 203 and Figure
204
Figure 203
Figure 204
16)
Secure OPTIC Heater mounting Plate (497-0524577) to dispenser wall by installing
one 6-32 screw (006-8611215) fully into the bracket to hold the assembly in place.
The screw prevents the bracket from backing out. It will hit a metal bracket in the
pump wall if you try to slide the assembly backwards. See Figure 205 and Figure
206 below.