100
Figure 179
Note: All cables and cable bundles must be re-routed away from the front of the
heater exit.
Note: In the example below, a cable bundle initially wraps around the side of the power
supply bracket plate (497-0517788), which could potentially lie in front of the heater.
This cable bundle must be re-routed to go underneath the power supply bracket plate.
6)
First cut the cable restraint to enable more cable slack, then tucking cable bundle
under the bracket and securing with supplied cable tie (006-8616073) through the
existing hole as shown in Figure 180 below.