Chapter 13 ANALOG OUTPUT
13.1 Output Terminal Connection
F-52, 53, 54, 55
169
●
F-53 to F-55
Terminal
No.
Connection cable
Output
1
For CH1
Shield
CH1
Ground
Red
CH1
Temperature
White
CH1 measure-
ment data
2
For CH2
Shield
CH2
Ground
Red
CH2
Temperature
White
CH2 measure-
ment data
3
For alarm
Shield
Alarm ground
Red
CH1 alarm
White
CH2 alarm
BNC connector
Shield White Red
Alarm
Exclusive cable for analog output
Serial communication connector
Analog output terminal
Summary of Contents for F-52