Service Manual Chapter8. CDU (Cash Dispenser Unit)
©
Nautilus Hyosung, Inc.
All Rights Reserved.
8-19
4. Remaining Note Sensor
1) CS6 / CS16 / CS26 / CS42
①
Remove the CS6 sensor from the main B/D to replace it. (See the main B/D
replacement section)
②
Remove the sensor bracket M3 screws (2 places each).
③
Press the snap lock in the rear of the sensor bracket with your hand and, then
remove the sensor
④
Remove the connector. Be careful not to break the connector pin when removing.
⑤
Replace the sensor.
⑥
Connect the connector.
⑦
To assemble the sensor in the bracket, lock it from the front side and press the rear
side to fix it.
<Note!>
Adjust the sensor by running the variable resistance so that it generates a current
below 1.0V if there is cash available and above 3.0V if no cash is available.
Variable
resistance
CS6
CS42