Chapter8. CDU (Cash Dispenser Unit) Service Manual
8-22
©
Nautilus Hyosung, Inc.
All Rights Reserved.
3. Gate Solenoid Assembly
①
Remove the solenoid power cable.
②
Remove the
φ
2 E-ring.
③
Unscrew the solenoid bracket screws (M4, 2 places).
④
Unscrew the solenoid fixing screws (M4, 4 places).
⑤
Assemble in the reverse order -
④
~
①
after replacing a solenoid assembly. Adjust
the gate according to the standard (8-27page).
Φ
2 E-RING
44950404
44531901
GATE SOLENOID ASSY
(P/N : 72842301)