Service Manual Chapter3. User Handling Unit
©
Nautilus Hyosung, Inc.
All Rights Reserved.
3-5
Designed viewing
direction
▪
Viewing angle with optimum grayscale : normal axis
Color gamut
At LCD panel center
60% (typ.) [against NTSC color space]
Response time
Ton (white 90%
→
black 10%) + Tpff (black 10 %
→
white 90 %) 16 ms (typ.)
Luminance
At IBL = 7.5mArms/lamp
250cd/m
2
(typ.)
Signal system
LVDS 1 port
[RGB : 8-bit, Dot clock (CLK), Data enable (DE)]
Power supply voltage
LCD panel signal processing board : 3.3V
Backlight
Edge light type : 2 cold cathode fluorescent lamps
- Replaceable part
▪
Lamp holder set : Type No. 150LHS21
Power consumption
At IBL=7.5mArms/lamp and checkered flag pattern
9.5W (typ.)
Mechanical
Specifications
Module
size
326.5 ± 0.5(W) x 253.5 ± 0.5(H) x 11.2 ± 0.5 (D)
Display
area
304.128 (W) x 228.096 (H)
Weight
1000 (typ.)
▶
Disassembling the LCD assembly
1. Insert the key and turn it clockwise.
2. Pull the front panel outward and turn off the power.